AmpFLSTR® Identifiler® Plus PCR Amplification Kit

Optimized for casework, the AmpFLSTR® Identifiler® Plus PCR Amplification Kit enables forensic analysts to recover more interpretable results from a wider range of DNA evidence samples with increased confidence. The new kit includes the same primers and allelic ladder as the wide ...

Specifications

New Product
New additions to lifetechnologies.com
Label or Dye
PET®
NED™
VIC®
LIZ®
FAM™
Regulatory Statement
For Forensic or Paternity Use Only.

Related Applications

4486467
084d6d6e3d475baf3a4ae0c38a561ce9_CmgtBuyProduct

AmpFLSTR® Identifiler® Plus PCR Amplification Kit

Optimized for casework, the AmpFLSTR® Identifiler® Plus PCR Amplification Kit enables forensic analysts to recover more interpretable results from a wider range of DNA evidence samples with increased confidence. The new kit includes the same primers and allelic ladder as the wide ...

Specifications

Label or Dye
PET®
LIZ®
FAM™
VIC®
NED™
Shipping Condition
 Dry Ice
Regulatory Statement
For Forensic or Paternity Use Only.

Related Applications

A26182
4133d256ce70754749043bf8bf3b074b_CmgtBuyProduct

AmpFLSTR® Identifiler® Direct PCR Amplification Kit & Prep-n- Go™ Buffer, for buccal swabs

The AmpFLSTR® Identifiler® Direct PCR Amplification Kit & Prep-n-Go™ Buffer (for Buccal Swabs) combines the features of our AmpFLSTR® Identifiler® Direct PCR Amplification Kit with the convenience of sample processing using our Prep-n-Go™ Buffer (for Buccal Swabs). The Identifile ...

Specifications

Platform
3100-Avant™ Genetic Analyzer
3130 Genetic Analyzer
3500 Genetic Analyzer
GeneAmp® 9600
3500xL Genetic Analyzer
3730 DNA Analyzer
3130xl Genetic Analyzer
Technique
STR (Short Tandem Repeat) Analysis
Polymerase
AmpliTaq Gold® DNA Polymerase
Label or Dye
PET®
LIZ®
VIC®
NED™
FAM™
Amplicon Size
<360 bp
Sample Volume
25 µl⁄reaction
Reaction Format
SuperMix or Master Mix
Sample Type (Specific)
Buccal Swab
Forensic Sample
Matrix and Size Standards
GeneScan™ 500 and 600 LIZ® Size Standards
Matrix Standard Set DS-33
Regulatory Statement
For Forensic or Paternity Use Only.

Related Applications

4473289
4d877ce680aac86a22b573c749fc0d1f_CmgtBuyProduct

AmpFLSTR® Identifiler® Direct PCR Amplification Kit

The AmpFLSTR® Identifiler® Direct PCR Amplification Kit enables direct amplification of the 16 loci included in the Identifiler® Kit, eliminating the need to perform DNA extraction or purification steps for DNA database and other single source reference samples. Blood or buccal s ...

Specifications

Platform
3100-Avant™ Genetic Analyzer
310 Genetic Analyzer
3130xl Genetic Analyzer
3730 DNA Analyzer
3500xL Genetic Analyzer
GeneAmp® 9700
GeneAmp® 9600
3500 Genetic Analyzer
Technique
STR (Short Tandem Repeat) Analysis
Polymerase
AmpliTaq Gold® DNA Polymerase
Label or Dye
PET®
NED™
VIC®
LIZ®
FAM™
Amplicon Size
<360 bp
Sample Volume
25 µl⁄reaction
Reaction Format
SuperMix or Master Mix
Sample Type (Specific)
Forensic Sample
Whatman FTA Cards Samples
Saliva
Blood
DNA (Genomic)
Matrix and Size Standards
GeneScan™ 500 LIZ® Size Standard
Matrix Standard Set DS-33
Shipping Condition
Dry Ice
Regulatory Statement
For Forensic or Paternity Use Only.

Related Applications

4408580
5d6ad861c685e0e5baa08c403b3f17d9_CmgtBuyProduct

AmpFLSTR® Identifiler® PCR Amplification Kit

The AmpFLSTR® Identifiler® PCR Amplification Kit is the single most discriminating and widely used STR based kit for human identification applications from Applied Biosystems®. The Identifiler kit amplifies 15 loci and Amelogenin in a single tube and provides loci consistent with ...

Specifications

Platform
3100-Avant™ Genetic Analyzer
310 Genetic Analyzer
3130xl Genetic Analyzer
3730 DNA Analyzer
3500xL Genetic Analyzer
GeneAmp® 9700
GeneAmp® 9600
3500 Genetic Analyzer
Technique
STR (Short Tandem Repeat) Analysis
Polymerase
AmpliTaq Gold® DNA Polymerase
Label or Dye
PET®
NED™
VIC®
LIZ®
FAM™
Amplicon Size
<360 bp
Sample Volume
25 µl⁄reaction
Reaction Format
SuperMix or Master Mix
Sample Type (Specific)
Forensic Sample
DNA (Genomic)
Matrix and Size Standards
GeneScan™ 500 LIZ® Size Standard
Matrix Standard Set DS-33
Shipping Condition
Dry Ice
Regulatory Statement
For Forensic or Paternity Use Only.

Related Applications

4322288
422eb067567085520d51f146823ca8bb_CmgtBuyProduct

VeriFiler™ Direct/Identifiler™ Direct Paternity Testing Bundle

The VeriFiler™ Direct/Identifiler™ Direct Paternity Testing Bundle contains these three products in a discounted combo pack: ...

Specifications

Platform
3130 Genetic Analyzer
3130xl Genetic Analyzer
3500 Genetic Analyzer
Veriti® Thermal Cycler
GeneAmp® 9700
3500xL Genetic Analyzer
Technique
STR (Short Tandem Repeat) Analysis
Polymerase
AmpliTaq Gold® DNA Polymerase
Label or Dye
PET®
LIZ®
VIC®
NED™
FAM™
Amplicon Size
<300 bp
Sample Volume
25 µl⁄reaction
Reaction Format
SuperMix or Master Mix
Matrix and Size Standards
Matrix Standard: DS-33 Matrix Standard Kit (Dye Set G5)
Size Standard: GeneScan&trade 600 LIZ® Size Standard v2.0
Regulatory Statement
For Paternity Use Only. Not for use in Research or Clinical Diagnostic applications.

Related Applications

4480504
502f6a1c7307030689c02b2c7f0b3567_CmgtBuyProduct

AmpFLSTR® Identifiler® PCR Amplification Kit User′s Manual

This is the User Guide Manual for the AmpFLSTR® Identifiler® PCR Amplification Kit. ...

Specifications

Shipping Condition
Room Temperature
Regulatory Statement
For Forensic or Paternity Use Only.

Related Applications

4323291
7568ea3746ca9ac70c45df5f2aff0499_CmgtBuyProduct

AmpFLSTR® Identifiler® Plus PCR Amplification Kit User Guide

This is the User Guide for the AmpFLSTR® Identifiler® Plus PCR Amplification Kit. ...

Specifications

Shipping Condition
Room Temperature
Regulatory Statement
For Forensic or Paternity Use Only.

Related Applications

4440211
3f988e4c56af90f06626529d7cecfb49_CmgtBuyProduct

AmpFLSTR® Identifiler® Direct PCR Amplification Kit User′s Guide

This is the User Guide Manual for the AmpFLSTR® Identifiler® Direct PCR Amplification Kit. ...

Specifications

Shipping Condition
Room Temperature
Regulatory Statement
For Forensic or Paternity Use Only.

Related Applications

4415125
28c274e997fc3baffcaadf1011c2ac53_CmgtBuyProduct

AmpFLSTR® SGM Plus® PCR Amplification Kit User′s Manual

This is the User Guide Manual for the AmpFLSTR® SGM Plus® PCR Amplification Kit. ...

Specifications

Platform
3100-Avant™ Genetic Analyzer
3130 Genetic Analyzer
3500 Genetic Analyzer
GeneAmp® 9600
GeneAmp® 9700
3500xL Genetic Analyzer
3730 DNA Analyzer
3130xl Genetic Analyzer
310 Genetic Analyzer
Technique
STR (Short Tandem Repeat) Analysis
Polymerase
AmpliTaq Gold® DNA Polymerase
Label or Dye
JOE™
FAM™
NED™
ROX™
Amplicon Size
<360 bp
Sample Volume
50 µl⁄reaction
Reaction Format
SuperMix or Master Mix
Sample Type (Specific)
Forensic Sample
DNA (Genomic)
Matrix and Size Standards
GeneScan™ 500 LIZ® Size Standard
Matrix Standard Set DS-33
Shipping Condition
Room Temperature
Regulatory Statement
For Forensic or Paternity Use Only.

Related Applications

4309589
e06a2abe946e60a635fccc04f9e665fd_CmgtBuyProduct

AmpFLSTR® Profiler® Manual and Filter Set F Module File Disk

This contains protocols and supporting information for the AmpFLSTR® Profiler® Kit and Filter Set F Module File disk. ...

Specifications

Platform
3100-Avant™ Genetic Analyzer
3130xl Genetic Analyzer
3730 DNA Analyzer
3500xL Genetic Analyzer
GeneAmp® 9700
GeneAmp® 9600
3500 Genetic Analyzer
310 Genetic Analyzer
Technique
STR (Short Tandem Repeat) Analysis
Polymerase
AmpliTaq Gold® DNA Polymerase
Label or Dye
JOE™
NED™
ROX™
FAM™
Amplicon Size
<350 bp
Sample Volume
50 µl⁄reaction
Reaction Format
SuperMix or Master Mix
Sample Type (Specific)
Forensic Sample
DNA (Genomic)
Matrix and Size Standards
Matrix Standard Set DS-32
GeneScan™ 500 ROX™ Internal Lane Size Standard
Regulatory Statement
For Forensic or Paternity Use Only.

Related Applications

403067
87ec5d67ed6d46528da6f00402ea7d13_CmgtBuyProduct

VALID™ Software v1.0

LIfe Technologies® offers the world’s first commercially available quality assurance assistance software that streamlines the experimental design, accelerates data analysis, automates report generation, and manages validation projects and documentation for Human Identification La ...

Specifications

Platform
3100-Avant™ Genetic Analyzer
3130 Genetic Analyzer
3130xl Genetic Analyzer
310 Genetic Analyzer
Software Type
Forensic STR Fragment Analysis
Operating System
Windows 2000 Pro (Service Pack 4)
Windows XP Pro (Service Pack 2)
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

9c1115a1b2bc1cf1b3bdf951cd512af3_CmgtBuyProduct

AmpFLSTR® Profiler® PCR Amplification Kit User′s Manual

This is the user's manual for the AmpFLSTR® Profiler® PCR Amplification Kit. ...

Specifications

Shipping Condition
Room Temperature
Regulatory Statement
For Forensic or Paternity Use Only.

Related Applications

402945
e956e0d273defe26bee5711611ea87d9_CmgtBuyProduct

Quantifiler® Trio DNA Quantification Kit

The Quantifiler® Trio DNA Quantification Kit is a robust kit that enables forensic laboratories to simultaneously obtain a quantitative and qualitative assessment of total human and human male DNA in a single, highly sensitive real-time PCR reaction. This guides selection of the ...

Specifications

New Product
New additions to lifetechnologies.com
Target Gene
Y chromosome
small autosomal (SA) human target
, large autosomal (LA) human target
Regulatory Statement
For Forensic or Paternity Use Only.

Related Applications

4482910
6d01a496bc290b6a60cc37be49d617a6_CmgtBuyProduct