CaptureSelect™ LC-kappa (mur) Affinity Matrix

The CaptureSelect™ LC-kappa (mur) Affinity Matrix enables purification of murine (mouse, rat, and guinea pig) immunoglobulins and Fab fragments without cross reactivity towards bovine immunoglobulins. The ligand is directed towards a unique domain on the constant part of the kapp ...

Specifications

Format
Bulk Media
Immobilized Phase
Anti LC-kappa
Column or Resin Type
Bulk Resins
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

191315005
014953baf2bc2c3582a129628232ad13_CmgtBuyProduct

CaptureSelect™ LC-kappa (Hu) Affinity Matrix

This is one of a group of CaptureSelect™ Antibody Toolbox® affinity resins designed for the simple, single-step purification of all antibody subtypes and fragments. Unlike the common bacterial coat protein matrices (e.g., Protein A, G, and L), the Antibody Toolbox resins were spe ...

Specifications

Format
Bulk Media
Immobilized Phase
Anti LC-kappa
Column or Resin Type
Bulk Resins
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

083305
dac5487db26c78e12728598dd9dfd2e0_CmgtBuyProduct

POROS® CaptureSelect® LC Kappa Affinity Column, 4.6 x 50 mm

Analytical groups supporting biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentation harvests, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreac ...

Specifications

Format
Column
Platform
HPLC
Flow Rate
Up to 5000 cm⁄hr
Pore Size
0.16 micron
Dimensions
4.6 mm (diameter) x 50 mm (length)
Reactivity
Human
Particle Size
20 micron
Support Matrix
Polystyrenedivinylbenzene
Target Molecule
Kappa Light Chain
Binding Strength
14.5 mg/ml dynamic binding capacity
Immobilized Phase
CaptureSelect® LC Kappa
Column or Resin Type
PrePacked Column
Affinity Column
Elution Volume - max
1.6 ml
Elution Volume - min
800 µl
Sample Type (Specific)
Cell Culture Supernatants
Maximum Operating Pressure
180 bar
High Throughput Compatibility
Not High Throughput-Compatible (Manual)
Shipping Condition
Wet Ice

Related Applications

4469162
10f32bd07fbddae2559736d8c1c9571f_CmgtBuyProduct

POROS® CaptureSelect® LC Kappa Affinity Column, 4.6 x 100 mm

Analytical groups supporting biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentation harvests, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreac ...

Specifications

Format
Column
Platform
HPLC
Flow Rate
Up to 5000 cm⁄hr
Pore Size
0.16 micron
Dimensions
4.6 mm (diameter) x 100 mm (length)
Reactivity
Human
Particle Size
20 micron
Support Matrix
Polystyrenedivinylbenzene
Target Molecule
Kappa Light Chain
Binding Strength
14.5 mg/ml dynamic binding capacity
Immobilized Phase
CaptureSelect® LC Kappa
Column or Resin Type
PrePacked Column
Affinity Column
Elution Volume - max
3.4 ml
Elution Volume - min
1.7 ml
Sample Type (Specific)
Cell Culture Supernatants
Maximum Operating Pressure
180 bar
High Throughput Compatibility
Not High Throughput-Compatible (Manual)
Shipping Condition
Wet Ice

Related Applications

4469167
469611ebdf3f038c8a93112f6c3eb0ec_CmgtBuyProduct

POROS® CaptureSelect® LC Kappa Affinity Column, 10 x 100 mm

Analytical groups supporting biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentation harvests, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreac ...

Specifications

Format
Column
Platform
HPLC
Flow Rate
Up to 5000 cm⁄hr
Pore Size
0.16 micron
Dimensions
10 mm (diameter) x 100 mm (length)
Reactivity
Human
Particle Size
20 micron
Support Matrix
Polystyrenedivinylbenzene
Target Molecule
Kappa Light Chain
Binding Strength
14.5 mg/ml dynamic binding capacity
Immobilized Phase
CaptureSelect® LC Kappa
Column or Resin Type
PrePacked Column
Affinity Column
Elution Volume - max
15.8 ml
Elution Volume - min
7.9 ml
Sample Type (Specific)
Cell Culture Supernatants
Maximum Operating Pressure
180 bar
High Throughput Compatibility
Not High Throughput-Compatible (Manual)
Shipping Condition
Wet Ice

Related Applications

4469172
48154e219be9b4b7a68a7e0e0216b31c_CmgtBuyProduct

POROS® CaptureSelect® LC Kappa Affinity Column, 2.1 x 30 mm

Analytical groups supporting biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentation harvests, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreac ...

Specifications

Format
Column
Platform
HPLC
Flow Rate
Up to 5000 cm⁄hr
Pore Size
0.16 micron
Dimensions
2.1 mm (diameter) x 30 mm (length)
Reactivity
Human
Particle Size
20 micron
Support Matrix
Polystyrenedivinylbenzene
Target Molecule
Kappa Light Chain
Binding Strength
14.5 mg/ml dynamic binding capacity
Immobilized Phase
CaptureSelect® LC Kappa
Column or Resin Type
PrePacked Column
Affinity Column
Elution Volume - max
200 µl
Elution Volume - min
100 µl
Sample Type (Specific)
Cell Culture Supernatants
Maximum Operating Pressure
180 bar
High Throughput Compatibility
Not High Throughput-Compatible (Manual)
Shipping Condition
Wet Ice

Related Applications

4469149
3f383a2a95a23943bce2e0b90c3d38bf_CmgtBuyProduct

CaptureSelect™ Biotin Anti-LC-kappa (Murine) Conjugate

CaptureSelect™ Biotin Anti-LC-kappa (mur) Conjugate consists of a 13 kDa llama antibody fragment (affinity ligand) that specifically binds to the constant domain of kappa light chains of mouse and rat antibodies. The affinity ligand is chemically conjugated to biotin via an appro ...

Specifications

Ligand Type
Antibody
Target Isotype
Kappa Light Chain
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

7103152100
ca33598cda64e34de12e6986bd692480_CmgtBuyProduct

CaptureSelect™ Biotin Anti-LC-kappa (Human) Conjugate

CaptureSelect™ Biotin Anti-LC-kappa (Hu) Conjugate consists of a 13 kDa llama antibody fragment (affinity ligand) that specifically binds to the constant domain of human kappa light chains. The affinity ligand is chemically conjugated to biotin via an appropriate spacer that reta ...

Specifications

Ligand Type
Antibody
Target Isotype
Kappa Light Chain
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

7103272100
294a1bca86d343d3209fce4100088c96_CmgtBuyProduct

CaptureSelect™ LC-lambda (rat) Affinity Matrix

The CaptureSelect™ LC-lambda (rat) Affinity Matrix contains a 13 kDa llama antibody fragment recognizing the lambda light chain of Ig's from rat and guinea pig. The ligand is directed towards a unique domain on the constant part of the lambda light chain of immunoglobulins, whic ...

Specifications

Format
Bulk Media
Immobilized Phase
Anti LC-lambda
Column or Resin Type
Bulk Resins
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

194324050
03849edade5ce59beb5ffa3153848758_CmgtBuyProduct

CaptureSelect™ LC-lambda (mouse) Affinity Matrix

The CaptureSelect™ LC-lambda (mouse) Affinity Matrix contains a 13 kDa llama antibody fragment recognizing the lambda light chain of mouse Ig’s. The ligand is directed towards a unique domain on the constant part of the lambda light chain of immunoglobulins, which enables purific ...

Specifications

Format
Bulk Media
Immobilized Phase
Anti LC-lambda
Column or Resin Type
Bulk Resins
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

194323005
2c39739a9fc4937a3bb885674663e7aa_CmgtBuyProduct

CaptureSelect™ LC-lambda (ung) Affinity Matrix

The CaptureSelect™ LC-lambda (ung) Affinity Matrix enables depletion/purification of ungulate Ig’s, Fab fragments, and free light chains without cross reactivity to human and mouse immunoglobulins. The ligand binds to the constant part of the lambda light chain of hoofed animals ...

Specifications

Format
Bulk Media
Immobilized Phase
Anti LC-lambda
Column or Resin Type
Bulk Resins
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

191314005
9588bcc1f83e72b455e54297320786ab_CmgtBuyProduct

CaptureSelect™ Biotin Anti-Free LC-kappa (Human) Conjugate

CaptureSelect™ Biotin Anti-Free LC-kappa (Hu) Conjugate consists of a 13 kDa llama antibody fragment (affinity ligand) that binds highly selectively to free human kappa light chains and dimers thereof. The functionality is based on recognition of an epitope on the human CL-kappa ...

Specifications

New Product
New additions to lifetechnologies.com
Ligand Type
Antibody
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

7103292100
867e59441eff8047977cd94bd27e6afe_CmgtBuyProduct

POROS® GoPure™ PI Pre-packed Column, 0.5 x 5 cm, 1 mL

GoPure™ 0.5 cmD pre-packed columns are intended for the screening of POROS® ion exchange resins or for small scale purification. These pre-packed columns are ready to connect and have the following features: ...

Specifications

Format
Individual
Platform
FPLC
Particle Size
50 micron
Immobilized Phase
Polyethyleneimine
Column or Resin Type
Anion Exchange Column
Sample Type (Specific)
Biopharmaceutical Purification Sample
Serum
Cell Culture Supernatants
Maximum Operating Pressure
30 bar
High Throughput Compatibility
Automated Protocols
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

4481318
752e3dcb58df7dd519085de32a59860b_CmgtBuyProduct

POROS® GoPure™ HS Pre-packed Column, 0.5 x 5 cm, 1 mL

GoPure™ 0.5 cmD pre-packed columns are intended for the screening of POROS® ion exchange resins or for small scale purification. These pre-packed columns are ready to connect and have the following features: ...

Specifications

Format
Individual
Platform
FPLC
Particle Size
50 micron
Immobilized Phase
Sulphopropyl
Column or Resin Type
Cation Exchange Column
Sample Type (Specific)
Biopharmaceutical Purification Sample
Cell Culture Supernatants
Serum
Maximum Operating Pressure
30 bar
High Throughput Compatibility
Automated Protocols
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

4481316
29bf6b0a47fbd02bbb284f331884cec3_CmgtBuyProduct

POROS® GoPure™ HQ Pre-packed Column, 0.5 x 5 cm, 1 mL

GoPure™ 0.5 cmD pre-packed columns are intended for the screening of POROS® ion exchange resins or for small scale purification. These pre-packed columns are ready to connect and have the following features: ...

Specifications

Format
Individual
Platform
FPLC
Particle Size
50 micron
Immobilized Phase
Quaternized Polyethyleneimine
Column or Resin Type
Anion Exchange Column
Sample Type (Specific)
Biopharmaceutical Purification Sample
Serum
Cell Culture Supernatants
Maximum Operating Pressure
30 bar
High Throughput Compatibility
Automated Protocols
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

4481315
44ab621687ebb9167e84b7150ed94567_CmgtBuyProduct