CaptureSelect™ LC-lambda (rat) Affinity Matrix

The CaptureSelect™ LC-lambda (rat) Affinity Matrix contains a 13 kDa llama antibody fragment recognizing the lambda light chain of Ig's from rat and guinea pig. The ligand is directed towards a unique domain on the constant part of the lambda light chain of immunoglobulins, whic ...

Specifications

Format
Bulk Media
Immobilized Phase
Anti LC-lambda
Column or Resin Type
Bulk Resins
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

194324050
03849edade5ce59beb5ffa3153848758_CmgtBuyProduct

CaptureSelect™ LC-lambda (mouse) Affinity Matrix

The CaptureSelect™ LC-lambda (mouse) Affinity Matrix contains a 13 kDa llama antibody fragment recognizing the lambda light chain of mouse Ig’s. The ligand is directed towards a unique domain on the constant part of the lambda light chain of immunoglobulins, which enables purific ...

Specifications

Format
Bulk Media
Immobilized Phase
Anti LC-lambda
Column or Resin Type
Bulk Resins
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

194323010
68e0b1b0ff91e9c817707d6d9c9c0fcb_CmgtBuyProduct

CaptureSelect™ LC-lambda (ung) Affinity Matrix

The CaptureSelect™ LC-lambda (ung) Affinity Matrix enables depletion/purification of ungulate Ig’s, Fab fragments, and free light chains without cross reactivity to human and mouse immunoglobulins. The ligand binds to the constant part of the lambda light chain of hoofed animals ...

Specifications

Format
Bulk Media
Immobilized Phase
Anti LC-lambda
Column or Resin Type
Bulk Resins
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

191314005
9588bcc1f83e72b455e54297320786ab_CmgtBuyProduct

CaptureSelect™ LC-lambda (Hu) Affinity Matrix

This is one of a group of CaptureSelect™ Antibody Toolbox® affinity resins designed for the simple, single-step purification of all antibody subtypes and fragments. Unlike the common bacterial coat protein matrices (e.g., Protein A, G, and L), the Antibody Toolbox resins were spe ...

Specifications

Format
Bulk Media
Immobilized Phase
Anti LC-lambda
Column or Resin Type
Bulk Resins
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

084910
52311a595ac7cf7ee05f42efc34deaa9_CmgtBuyProduct

CaptureSelect™ LC-lambda (ung) Affinity Matrix

This is one of a group of CaptureSelect™ Antibody Toolbox® affinity resins designed for the simple, single-step purification of all antibody subtypes and fragments. Unlike the common bacterial coat protein matrices (e.g., Protein A, G, and L), the Antibody Toolbox resins were spe ...

Specifications

Format
Bulk Media
Immobilized Phase
Anti LC-lambda
Column or Resin Type
Bulk Resins
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

191314050
aa4fca6013d807a6766008344e1ce587_CmgtBuyProduct

POROS® CaptureSelect® LC Lambda Affinity Column, 4.6 x 50 mm

Analytical groups supporting biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentation harvests, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreac ...

Specifications

Format
Column
Platform
HPLC
Flow Rate
Up to 5000 cm⁄hr
Pore Size
0.16 micron
Dimensions
4.6 mm (diameter) x 50 mm (length)
Reactivity
Human
Particle Size
20 micron
Support Matrix
Polystyrenedivinylbenzene
Target Molecule
Lambda Light Chain
Binding Strength
10.0 mg/ml dynamic binding capacity
Immobilized Phase
CaptureSelect® LC Lambda
Column or Resin Type
PrePacked Column
Affinity Column
Elution Volume - max
1.6 ml
Elution Volume - min
800 µl
Sample Type (Specific)
Cell Culture Supernatants
Maximum Operating Pressure
180 bar
High Throughput Compatibility
Not High Throughput-Compatible (Manual)
Shipping Condition
Wet Ice

Related Applications

4469163
48a9f4d544b8ea44c64055e29e81285d_CmgtBuyProduct

POROS® CaptureSelect® LC Lambda Affinity Column, 4.6 x 100 mm

Analytical groups supporting biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentation harvests, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreac ...

Specifications

Format
Column
Platform
HPLC
Flow Rate
Up to 5000 cm⁄hr
Pore Size
0.16 micron
Dimensions
4.6 mm (diameter) x 100 mm (length)
Reactivity
Human
Particle Size
20 micron
Support Matrix
Polystyrenedivinylbenzene
Target Molecule
Lambda Light Chain
Binding Strength
10.0 mg/ml dynamic binding capacity
Immobilized Phase
CaptureSelect® LC Lambda
Column or Resin Type
PrePacked Column
Affinity Column
Elution Volume - max
3.4 ml
Elution Volume - min
1.7 ml
Sample Type (Specific)
Cell Culture Supernatants
Maximum Operating Pressure
80 bar
High Throughput Compatibility
Not High Throughput-Compatible (Manual)
Shipping Condition
Wet Ice

Related Applications

4469168
90197bc8f38e59383d79d1498757e57f_CmgtBuyProduct

POROS® CaptureSelect® LC Lambda Affinity Column, 10 x 100 mm

Analytical groups supporting biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentation harvests, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreac ...

Specifications

Format
Column
Platform
HPLC
Flow Rate
Up to 5000 cm⁄hr
Pore Size
0.16 micron
Dimensions
10 mm (diameter) x 100 mm (length)
Reactivity
Human
Particle Size
20 micron
Support Matrix
Polystyrenedivinylbenzene
Target Molecule
Lambda Light Chain
Binding Strength
10.0 mg/ml dynamic binding capacity
Immobilized Phase
CaptureSelect® LC Lambda
Column or Resin Type
PrePacked Column
Affinity Column
Elution Volume - max
15.8 ml
Elution Volume - min
7.9 ml
Sample Type (Specific)
Cell Culture Supernatants
Maximum Operating Pressure
180 bar
High Throughput Compatibility
Not High Throughput-Compatible (Manual)
Shipping Condition
Wet Ice

Related Applications

4469173
92e908c80626139b872f1ef23777299a_CmgtBuyProduct

POROS® CaptureSelect® LC Lambda Affinity Column, 2.1 x 30 mm

Analytical groups supporting biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentation harvests, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreac ...

Specifications

Format
Column
Platform
HPLC
Flow Rate
Up to 5000 cm⁄hr
Pore Size
0.16 micron
Dimensions
2.1 mm (diameter) x 30 mm (length)
Reactivity
Human
Particle Size
20 micron
Support Matrix
Polystyrenedivinylbenzene
Target Molecule
Lambda Light Chain
Binding Strength
10.0 mg/ml dynamic binding capacity
Immobilized Phase
CaptureSelect® LC Lambda
Column or Resin Type
PrePacked Column
Affinity Column
Elution Volume - max
200 µl
Elution Volume - min
100 µl
Sample Type (Specific)
Cell Culture Supernatants
Maximum Operating Pressure
180 bar
High Throughput Compatibility
Not High Throughput-Compatible (Manual)
Shipping Condition
Wet Ice

Related Applications

4469150
cb897ebccbdfbf1da4293133d700f94c_CmgtBuyProduct

CaptureSelect™ Biotin Anti-LC-lambda (Human) Conjugate

CaptureSelect™ Biotin Anti-LC-lambda (Hu) Conjugate consists of a 13 kDa llama antibody fragment (affinity ligand) that specifically binds to the constant domain of human lambda light chains. The affinity ligand is chemically conjugated to biotin via an appropriate spacer that re ...

Specifications

Ligand Type
Antibody
Target Isotype
Lambda Light Chain
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

7103082100
e6df4ac440338bcdbcacec613659b42d_CmgtBuyProduct

CaptureSelect™ LC-kappa (mur) Affinity Matrix

The CaptureSelect™ LC-kappa (mur) Affinity Matrix enables purification of murine (mouse, rat, and guinea pig) immunoglobulins and Fab fragments without cross reactivity towards bovine immunoglobulins. The ligand is directed towards a unique domain on the constant part of the kapp ...

Specifications

Format
Bulk Media
Immobilized Phase
Anti LC-kappa
Column or Resin Type
Bulk Resins
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

191315005
014953baf2bc2c3582a129628232ad13_CmgtBuyProduct

POROS® GoPure™ XS Pre-packed Column, 0.5 x 5 cm, 1 mL

GoPure™ 0.5 cmD pre-packed columns are intended for the screening of POROS® ion exchange resins or for small scale purification. These pre-packed columns are ready to connect and have the following features: ...

Specifications

Format
Individual
Platform
FPLC
Particle Size
50 micron
Immobilized Phase
Sulphopropyl
Column or Resin Type
Cation Exchange Column
Sample Type (Specific)
Biopharmaceutical Purification Sample
Serum
Cell Culture Supernatants
Maximum Operating Pressure
30 bar
High Throughput Compatibility
Automated Protocols
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

4481317
7f4a444aa8ec0ace5c632fb99220bc98_CmgtBuyProduct

POROS® GoPure™ HS Pre-packed Column, 0.5 x 5 cm, 1 mL

GoPure™ 0.5 cmD pre-packed columns are intended for the screening of POROS® ion exchange resins or for small scale purification. These pre-packed columns are ready to connect and have the following features: ...

Specifications

Format
Individual
Platform
FPLC
Particle Size
50 micron
Immobilized Phase
Sulphopropyl
Column or Resin Type
Cation Exchange Column
Sample Type (Specific)
Biopharmaceutical Purification Sample
Serum
Cell Culture Supernatants
Maximum Operating Pressure
30 bar
High Throughput Compatibility
Automated Protocols
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

4481316
29bf6b0a47fbd02bbb284f331884cec3_CmgtBuyProduct

POROS® GoPure™ D Pre-packed Column, 0.5 x 5 cm, 1 mL

GoPure™ 0.5 cmD pre-packed columns are intended for the screening of POROS® ion exchange resins or for small scale purification. These pre-packed columns are ready to connect and have the following features: ...

Specifications

Format
Individual
Platform
FPLC
Particle Size
50 micron
Immobilized Phase
Dimethylaminopropyl
Column or Resin Type
Anion Exchange Column
Sample Type (Specific)
Biopharmaceutical Purification Sample
Serum
Cell Culture Supernatants
Maximum Operating Pressure
30 bar
High Throughput Compatibility
Automated Protocols
Regulatory Statement
For Research Use Only. Not for use in diagnostic procedures.

Related Applications

4481319