Cell Analysis Protocols

Experiment Protocol

3a8dc3c30441fd33a6fb3c8eb433eb2a_iProtocol

Immunoprecipitation Protocol Using Anti-GFP Antibodies

Experiment Protocol

dbc47abe8ef608d257c3972220628524_iProtocol

ActinRed™ 555 ReadyProbes® Reagent Protocol

Experiment Protocol

36021bba40a66a34c9bd2fb078222cd1_iProtocol

NucGreen® Dead 488 ReadyProbes® Reagent Protocol for Fixed Cells

Experiment Protocol

4992643fbe16e1b758fcc8ddd56b10a6_iProtocol

NucGreen® Dead 488 ReadyProbes® Reagent

Experiment Protocol

60c6b3d9b498c7fc256fc5a513d4cc13_iProtocol

CellTrace™ CFSE Cell Proliferation Kit Protocol

Experiment Protocol

1cfb6ecea56b5e74a5cc34b32deef14d_iProtocol

LIVE/DEAD® Fixable Dead Cell Stains

Experiment Protocol

dd7f336aafc162cb5b805358bcd0fbbe_iProtocol

CellTrace™ Violet Cell Proliferation Kit Protocol

Experiment Protocol

6aa8f7f9fb5ec8a9ee667fbf813fd901_iProtocol

BrdU Labeling and Detection Protocol

Experiment Protocol

6213f947aab6eb8cdb3a73cc5ff89215_iProtocol

PrestoBlue® Cell Viability Reagent for Microplates Protocol

Experiment Protocol

e3b5b25a71759990298b238c3284ed75_iProtocol

LIVE/DEAD® Violet Viability/Vitality Kit Protocol

Experiment Protocol

f3f7e6e1254ddd84aba4d03efb2ba9b7_iProtocol

How can I send .sds and .sdm data files to the Real Time PCR Technical Support team?

Product FAQ

Answer

These files are often large (>5 MB) and do not always transfer well through standard email. Please visit “Contact Us” on our website and reach out to your local Technical Support team first. They can then advise you on other methods we can use to share large files with you, such as .ftp or similar programs. Please be prepared to provide us with a detailed summary of your experiment, including information such as your instrument model number, assay ID, template input, master mix used, and thermal profile.

Answer Id: E2461

Was this answer helpful?

Yes
No
6d61bc22da834feeac4224b0973dbf1e_FAQ

Can I use probes with a Black Hole Quencher (BHQ) on Applied Biosystems® Real-Time PCR Systems?

Product FAQ

Answer

Yes, you can use probes with a BHQ on Applied Biosystems® Real-Time PCR Systems. However, you will need to set the quencher to NONE. Here is an example of a quencher setting based on the SDS software for the Applied Biosystems® 7500 Real-Time PCR System:

(1) After you create a new file, please click on TOOLS in the menu bar and choose DETECTOR MANAGER.
(2) Click FILE button on the lower left corner of the DETECTOR MANAGER window and choose NEW.
(3) In the NEW DETECTOR window, choose (NONE) in the dropdown list of QUENCHER DYE.

Answer Id: E2462

Was this answer helpful?

Yes
No
7c1188f54e08d22268f338770150ec02_FAQ

What is the concentration of primers in the primer-limited TaqMan® Endogenous Control Assays and what function does it have in my reaction?

Product FAQ

Answer

The final primer concentration for the primer-limited Endogenous Controls is 150 nM for the forward primer and 150 nM the reverse primer. Usually, the endogenous control genes are abundantly expressed. The limited primer concentration will force the PCR of the endogenous control to plateau early, so that it leaves enough dNTPs and enzyme for lower expressed target genes to be amplified.

Answer Id: E2463

Was this answer helpful?

Yes
No
bdf1443e71fa16257cc391ab64e0336b_FAQ

Can I check the end product of a TaqMan® Gene Expression Assay by running an agarose gel?

Product FAQ

Answer

Yes, you can check the end product on an agarose gel. If you use the TaqMan® Universal PCR Master Mix (including AmpErase® UNG, Cat. No. 4304437), we recommend running the gel immediately after the PCR, since the trace amount of AmpErase® UNG may digest the end product that contains double-stranded DNA with dUTP incorporated. The average length of amplicon ranges from 50-150 bp. The exact amplicon length is indicated on the detailed page of each assay on our website. You can get to that page by clicking on the Assay ID; the amplicon information is listed in the section "Assay Details".

Answer Id: E2464

Was this answer helpful?